E2K-L13MC1
Cảm biến phát hiện mức nước Omron
Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid
• Mount to bypass pipes.
• Fit a wide range of pipe diameters: 8 to 11 mm or 12 to 26 mm
• Built-in Amplifiers to save space.
Sensors
Sensing method |
Applicable pipe diameters |
Appearance | Output configuration/ Operation mode |
Model | |
---|---|---|---|---|---|
Capacitive | 8 to 11mm | NPN open-collector output | NO | E2K-L13MC1 2M | |
12 to 26 mm | E2K-L26MC1 2M |
last update: September 24, 2012
last update: September 24, 2012
Model | E2K-L13MC1 | E2K-L26MC1 | ||
---|---|---|---|---|
Applicable pipes | Materials | Non-metal | ||
Size | Diameter | 8 to 11 mm | 12 to 26 mm | |
Thickness | 1 mm max. | 1.5 mm max. | ||
Detectable object | Liquid * | |||
Repeat accuracy | ±0.2 mm max. | |||
Differential travel (Reference value, varies with pipe size and liquid.) |
0.6 to 5 mm | 0.3 to 3 mm | ||
Power supply voltage (operating voltage range) |
12 to 24 VDC (10.8 to 30 VDC), ripple (p-p): 10% max. | |||
Current consumption | 12 mA max. | |||
Control output | Load current | 100 mA max. | ||
Residual voltage | 1 V max. (Load current: 100 mA, Cable length: 2 m) | |||
Sensing liquid position | Indented mark position (For details, refer to Datasheet) | |||
Indicators | Detection indicator (orange) | |||
Ambient temperature range | Operating: 0 to 55°C (with no icing or condensation), Storage: -10 to 65°C (with no icing or condensation) | |||
Ambient humidity range | Operating/Storage: 25% to 85% (with no condensation) | |||
Temperature influence | ±4 mm of detection level at 23°C in the temperature range of 0 to 55°C (with pure water or 20% saline solution) (±6 mm for E2K-L13MC1 with pure water and a pipe diameter of 8 mm) |
|||
Voltage influence | ±0.5 mm of detection level at the rated voltage in rated voltage ±10% range | |||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | |||
Dielectric strength | 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case | |||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||
Shock resistance | Destruction: 500 m/s2 3 times each in X, Y, and Z directions | |||
Degree of protection | IP66 (IEC) | |||
Connection method | Pre-wired Models (Standard cable length: 2 m) | |||
Weight (packed state) | Approx. 70 g | |||
Materials | Case, Cover | Heat-resistant ABS | ||
Cable clamp | NBR | |||
Accessories | Two bands, Four slip-proof tubes, Instruction manual |
actual application.
1. If the specific inductive capacity or the specific electric conductivity of the liquid is too low, the liquid position may not be
detected since this sensor is a capacitive sensor.
2. If the quantity of liquid is too low or the change in quantity is too low in comparison to the change in liquid level because
the pipe is too thin or the walls of the pipe are too thick
3. If there is a viscous film on the inner pipe wall, large quantities of foam or air bubbles, or excessive buildup of dirt on
the inner pipe wall